ADC¶
Analog to digital converters, typically used for measuring voltages for sensors, battery voltage, etc.
Defines¶
MIRA_ADC_PIN_VDD¶
MIRA_ADC_PIN_DISABLED¶
Types¶
mira_adc_value_t¶
Enums¶
mira_adc_reference_t¶
Name | Description |
---|---|
MIRA_ADC_REF_VDD |
|
MIRA_ADC_REF_INT_3_6V |
Structs¶
mira_adc_context_t¶
Struct containing the context of an ADC channel.
Do not change this struct directly, use the modifier methods mira_adc_set_*().
Name | Type | Description |
---|---|---|
gpio_pin_p |
uint16_t |
|
gpio_pin_n |
uint16_t |
|
reference |
mira_adc_reference_t |
|
is_measuring |
mira_bool_t |
|
value |
mira_adc_value_t |
|
measuring_process |
struct process * |
Functions¶
mira_adc_init¶
Initialize the ADC module and an ADC context with default values.
Use this to set up the context block with default parameters and initialize the ADC module.
Parameters¶
Name | Description |
---|---|
context | Configuration block for the ADC. |
Return value¶
Name | Description |
---|---|
MIRA_SUCCESS | The initialization was successful. |
mira_adc_uninit¶
Uninitialize the ADC module.
Uninitializes the ADC module and aborts on-going measurement.
Parameters¶
Name | Description |
---|---|
context | Configuration block for the ADC. |
Return value¶
Name | Description |
---|---|
MIRA_SUCCESS | The initialization was successful. |
mira_adc_set_source_supply¶
Set the source of the ADC to the supply voltage.
Parameters¶
Name | Description |
---|---|
context | Configuration block for the ADC. |
Return value¶
Name | Description |
---|---|
MIRA_SUCCESS | The operation was successful. |
mira_adc_set_source_single¶
Set the source of the ADC to a single ended measurement.
Parameters¶
Name | Description |
---|---|
context | Configuration block for the ADC. |
pin | GPIO pin for the source (not analog pin number). |
Return value¶
Name | Description |
---|---|
MIRA_SUCCESS | The operation was successful. No error on wrong pin selection, mira_adc_measurement_start() detects that instead. |
mira_adc_set_source_diff¶
mira_status_t mira_adc_set_source_diff(mira_adc_context_t *context, mira_gpio_pin_t pin_p, mira_gpio_pin_t pin_n);
Set the source of the ADC to a differential measurement.
If CPU doesn't support differential measurements, this will be emulated by two consecutive measurements.
Parameters¶
Name | Description |
---|---|
context | Configuration block for the ADC. |
pin_p | GPIO pin for the positive source (not analog pin number). |
pin_n | GPIO pin for the negative soruce (not analog pin number). |
Return value¶
Name | Description |
---|---|
MIRA_SUCCESS | The operation was successful. No error on wrong pin selection, mira_adc_measurement_start() detects that instead. |
mira_adc_set_reference¶
Set the reference voltage of the analog conversion.
Sets the voltage that maps to the maximum voltage of the conversion.
Parameters¶
Name | Description |
---|---|
context | Configuration block for the ADC. |
reference | The reference for the conversion. |
Return value¶
Name | Description |
---|---|
MIRA_SUCCESS | The operation was successful. |
MIRA_ERROR_NOT_SUPPORTED | The reference voltage is not supported by the device. |
mira_adc_measurement_start¶
Start a measurement.
mira_adc_measurement_in_progress() returns MIRA_FALSE when the measurement is finished.
Correct procedure for measurement:
mira_status_t status;
mira_value_t value;
status = mira_adc_measurement_start(&context);
if(status == MIRA_SUCCESS) {
PROCESS_WAIT_UNTIL(!mira_adc_measurement_in_progress(&context));
status = mira_adc_measurement_finish(&context, &value);
... measurement result and status ...
} else {
... handle error ...
}
Call mira_adc_measurement_finish() for every successful mira_adc_measurement_start() call.
Parameters¶
Name | Description |
---|---|
context | Configuration block for the ADC. |
Return value¶
Name | Description |
---|---|
MIRA_SUCCESS | The operation was successful. |
MIRA_ERROR_NOT_INITIALIZED | The ADC module is not initialized. |
MIRA_ADC_ERROR_INVALID_PIN | A pin is invalid. |
MIRA_ADC_ERROR_CHANNEL_BUSY | A measurement is already in progress. |
mira_adc_measurement_in_progress¶
Check if the measurement is in progress.
Parameters¶
Name | Description |
---|---|
context | Configuration block for the ADC. |
Return value¶
Name | Description |
---|---|
MIRA_TRUE | A measurement is in progress. |
MIRA_FALSE | No measurement is in progress. |
mira_adc_measurement_finish¶
Finish the conversion and get the result.
Call this for each successful mira_adc_measurement_start() call, in order to free the ADC for other measurements.
Parameters¶
Name | Description |
---|---|
context | Configuration block for the ADC. |
value | Storage of the measurement value. Only set if successful. |
Return value¶
Name | Description |
---|---|
MIRA_SUCCESS | The operation was successful. |
MIRA_ADC_ERROR_NO_MEASUREMENT | Measurement failed to start. |